Critical Power Solutions
Power infrastructure is the foundation of every modernization program. DCS Global engineers, procures, and installs the complete power stack, from utility entrance to rack PDU.
UPS Systems
Double-conversion UPS in modular and monolithic configurations. Sizing from 10 kVA to multi-megawatt. Battery technology selection: VRLA and lithium-ion. Includes battery monitoring and replacement programs.
Power Distribution
Main distribution boards, sub-distribution panels, and rack-level PDUs. Redundant power paths (A/B feeds) to every rack. Remote monitoring and switching capability.
Generator Systems
Diesel and natural gas generators sized for full facility load plus startup surge. Automatic transfer switches with sub-second transfer time. Fuel storage and management.
Static Transfer Switches
Sub-cycle transfer between power sources for critical loads. Eliminates the brief interruption that occurs during UPS bypass.
Cooling Infrastructure
Cooling technology selection and deployment for power densities from 3 kW/rack to 100+ kW/rack.
Precision Air Cooling
CRAC and CRAH units for facilities up to 10 kW/rack average density. Hot aisle/cold aisle containment design and installation.
In-Row Cooling
Row-based cooling units for 5–15 kW/rack deployments. Chilled water and direct expansion configurations.
Rear-Door Heat Exchangers
Passive and active rear-door units for 10–30 kW/rack. Chilled water infrastructure design and installation.
Direct-to-Chip Liquid Cooling
Coolant distribution units (CDUs) and manifold systems for GPU and high-density CPU deployments. Required for sustained operation above 20 kW/rack.
Network Infrastructure
Network architecture design and deployment for enterprise data centers, from spine-leaf switching to high-speed interconnects for AI clusters.
Spine-Leaf Architecture
Design and deployment of spine-leaf switching topologies for predictable latency and horizontal scalability. 25/100/400 GbE configurations.
AI Cluster Interconnects
InfiniBand HDR/NDR and RoCEv2 network design for GPU clusters. 200–400 Gb/s per-node bandwidth configurations.
Network Security
Microsegmentation, firewall deployment, and network access control aligned with compliance framework requirements.
Out-of-Band Management
Dedicated management network for out-of-band access to all infrastructure components. Required for remote management and incident response.
Compute and Storage Deployment
Rack-and-stack, configuration, and integration of compute and storage hardware from all major OEMs.
Server Deployment
Rack-and-stack, BIOS configuration, firmware updates, and OS installation for servers from Dell, HPE, Lenovo, Supermicro, and other OEMs.
GPU Server Deployment
Specialized deployment for NVIDIA DGX, HGX, and OEM GPU servers. Includes liquid cooling integration and NVLink fabric configuration.
Storage Array Deployment
Rack-and-stack, cabling, and configuration for all-flash and hybrid storage arrays from Dell, NetApp, Pure Storage, HPE, and other OEMs.
Management Integration
Integration with existing DCIM, monitoring, and management platforms. API integration for automated provisioning.
Structured Cabling
Copper and fiber cabling infrastructure designed and installed to support current and future bandwidth requirements.
Fiber Backbone
Single-mode and multi-mode fiber backbone for high-speed interconnects. Pre-terminated trunk cables for rapid deployment.
Copper Cabling
Cat6A and Cat8 copper cabling for server access connections. Tested and certified to TIA-568 standards.
Cable Management
Overhead and underfloor cable management systems. Color-coded and labeled per ANSI/TIA-606 standards.
Testing and Certification
Every cable link tested and certified. Test reports delivered as project documentation.
Commissioning Services
Systematic testing of every infrastructure system under load, the verification step that confirms the delivered infrastructure performs as specified.
Power System Commissioning
UPS load testing, generator load bank testing, transfer switch testing, and power distribution verification. NETA-certified commissioning engineers.
Cooling System Commissioning
Cooling performance testing at target power densities. Airflow measurement and thermal mapping. Redundancy failover testing.
Network Commissioning
Throughput testing, latency measurement, and failover testing for all network paths. Documentation of as-built network configuration.
Integrated Systems Testing
Full facility testing under simulated production load. Verification that all systems perform as specified simultaneously.
Ongoing Managed Services
Post-modernization managed services to maintain infrastructure performance and extend the lifecycle of the investment.
Preventive Maintenance
Scheduled maintenance for UPS systems, cooling equipment, generators, and network infrastructure. Manufacturer-recommended service intervals.
Remote Monitoring
24/7 monitoring of power, cooling, and environmental conditions. Proactive alerting before conditions reach critical thresholds.
Break-Fix Services
On-site response for hardware failures. Parts inventory maintained for critical components. Response time SLAs aligned with workload criticality.
Technology Refresh Planning
Annual infrastructure review and technology refresh planning to maintain capability alignment with workload requirements.
Single-source accountability across all solutions